Key Factors When Installing PDUs in a Data Centre

Installing PDUs within a data centre requires careful planning. Facilities teams should consider equipment demand, rack layout, and electrical supply before installation begins. Effective planning supports safe power distribution and reduces the risk of overload.



Assessing Total Power Requirements



The first step involves calculating total power requirements. Each device within the rack uses a specific amount of current. Technicians should determine the combined load to ensure the selected PDU can handle connected equipment. Using a unit with insufficient capacity may result in circuit failure.



Selecting the Right Rack Configuration



Rack configuration directly affects PDU selection. Vertical PDUs offer multiple outlets without occupying equipment mounting space and are often positioned along the rear of the cabinet. Horizontal PDUs fit within rack units and are used where vertical space is restricted.



Input Power Type and Load Balancing



Input power type should be considered. Some PDUs are built for single-phase supply, while others accommodate three-phase input. Three-phase PDUs allow power to be distributed across separate circuits, which helps balancing electrical load.



Outlet Compatibility



Outlet type should align with equipment plug requirements. Data centres often use a mix of C13 and C19 connectors depending on device demand. Choosing suitable outlet types helps ensure compatibility with connected hardware.



Organised Cable Management



Cable management is another important factor. PDUs should be installed in a way that encourages organised routing of power leads. Clear routing minimises airflow obstruction and supports cooling efficiency.



Monitoring and Visibility



Monitoring features may also influence selection. Metered or intelligent PDUs enable facilities teams to monitor electrical usage. This visibility helps identifying underused capacity and supports future expansion planning.



Redundancy and Business Continuity



Redundancy planning is essential in facilities that require continuous operation. Automatic transfer switch PDUs enable equipment to remain powered if the primary supply fails. Backup systems maintain business continuity during electrical interruptions.



Post-Installation Checks



Routine inspection should follow installation. Technicians should verify secure mounting and inspect input connections. Periodic testing helps ensure electrical safety across the data centre.



PDUs support reliable power distribution across IT infrastructure. Proper installation safeguards equipment and maintains operational stability within data centre environments.